CAH/CAV

DOWNLOADS
CAH/CAV Datasheet
Power Range PN: 70W - 220W (Steady state or 100% ED)
Pulse Load 40s/120s:. . . . . . . . . . . . . . . . . . . . . 170W - 550W
10s/120s:. . . . . . . . . . . . . . . . . . . . . 320W - 1.9kW
5s/120s: . . . . . . . . . . . . . . . . . . . . . 410W - 3.1kW
1s/120s: . . . . . . . . . . . . . . . . . . . . . 1kW - 12 kW
De-rating Linear: PN @40°C to 0.75*PN @ 90°C
Environmental -40°C - 90°C
Resistance Tolerance ± 10% (standard) or ± 5% (optional)
Dielectric Strength 2500VAC in one minute
Working Voltage UL: 600VAC (850VDC)/ CE: 690VAC (1100VDC)
Insulation Resistance > 20MR
Protection class IP50
Max surface temperature 230°C - 270 °C
Connection Cables, UL: PTFE AWG 14 - 18
Thermo watch (optional) 130°C - 200°C
Approvals UL 508 (E208678) USA & Canada
Norms UL 508

Nominal load: steady state  70W - 220W
Pulse Load:

40s/120s : 170W - 660W
10s/120s : 320W - 2.4kW
5s/120s   : 410W - 4kW
1s/120s   : 1kW - 16 kW