Model # ES2000F
- These sensors are designed to be fixed by the case.
- They may be either horizontally or vertically mounted.
- The secondary connection Is made with a connector or cable.
- For ES and ESM sensors the primary conductor may be a cable or a bar.(1ms/hour)


Specifications |
Item Name | Cables |
Nominal Primary Current (rms) | 2000 A |
Secondary Current at IPN | 400 mA |
Supply Voltage (DC) | ±15 to ±24 V |
Product Type | Current sensors |
Mounting Type | Frame Mounting |
Measuring Range at ±15 V (Peak) | N/A |
Measuring Range at ±24 V (Peak) | ±3000 A |
Not Measurable Overload (Peak) | 20000 A |
Max. Measuring Resistance at ±15 V | N/A |
Max. Measuring Resistance at ±24 V | 11 O |
Min. Measuring Resistance at ±15 V | 0 O |
Min. Measuring Resistance at ±24 V | 0 O |
Turn Number | 5000 |
Accuracy at IPN | = ±0.5 % |
Accuracy at IPN (-5 to 70°C) | = ±1 % |
Accuracy at IPN (-20 to 70°C) | = ±1 % |
Offset Current | = ±0.25 mA |
Linearity | = 0.1 % |
Thermal Drift Coefficient (-5 to 70°C) | = 10 µA/ºC |
Thermal Drift Coefficient (-20 to 70°C) | = 10 µA/ºC |
Delay Time | = 1 µs |
di/dt Correctly Followed | = 100 A/µs |
Bandwidth | = 100 kHz |
Max. No-Load Consumption Current | = 25 mA |
Secondary Resistance | = 25 O |
Dielectric Strength Primary/Secondary | 4 kV |
Voltage Drop | = 1 V |
Mass | 1.5 kg |
Operating Temperature | -20 to +70 ºC |
Storage Temperature | -25 to +85 ºC |
Secondary Connection | 3 wires 200 mm |
Ordering Code | 1SBT152000R0001 |
Conformity | EN50178
EN61000-6-2
EN61000-6-4 |
Approvals | CE
RU
UL |
Features | General Data
Plastic case and insulating resin are self-extinguishing.
Fixing holes in the case moulding for two positions at right angles.
Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M.
Primary Connection
Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100°C.
Secondary Connection
Molex HE14 connector (ref. : 22-11- |
Details | Horizontal or vertical mounting
Once again ABB lead the field by giving installers a chance to choose between two ways of fastening sensors: horizontally or vertically. This flexibility means that ES sensors can be installed in any position.
This is a major breakthrough that greatly simplifies the task of systems integrators. The ES range is the ideal way of reducing the size of equipment.
Unbeatable Reliability
ESM-Industry-Current-Sensors-details.jpg
Designed using the 6 sigma |